MSChrom

Process, analyze and report your LC-MS and GC-MS data from your different instruments。

Mnova MSChrom (Formerly MS) provides a common interface for different vendor data and automates all functionality such as data importing and display, integration, background subtraction, display of extracted mass chromatograms, molecule match, enumeration of molecular formulae, etc.

 

>GET A LICENSE

Process and report your MSChrom data on your desktop!

Process and report your MSChrom data on your desktop!

MSChrom

Highlights

Common interface to visualize your data from different vendors.

Automate all functionality such as data importing and display, integration, background subtraction, display of extracted mass chromatograms, molecule match, enumeration of molecular formula, etc.

erify proposed structures by automatically matching molecular ion and isotope peaks, and potentially the MS/MS fragmentation peaks.

Predict the isotope clusters of a molecular formula with various adducts/losses and compare with observed mass spectrum.

Process and report MS data on your computer, improves the efficiency and save time for more complex problems.

Improve your efficiency by automating and customizing the analysis and reporting in batch mode or in real-time using Mnova scripts.

Make your analytical results searchable using Mnova DB!

Calculate MS peak purity. The Mnova MS peak purity shows the curves associated to the most abundant mass peaks under the selected chromatogram peak.

MSChrom

Features

  •       Open automatically your analytical data from instruments such as Agilent, Bruker, JEOL, Thermo, and Waters as well as data in mzData or mzXML formats (see supported formats here). Integrate peaks in the TIC, MS, and UV/ELSD traces (automatically or manually). Select mass spectra based on TIC peaks, with or without background subtraction and display them in centroid or profile mode. You can also co-add mass spectra manually as well as open NMR and MS data in the same document and analyze and report them together.

  •       Generate Extracted Mass/Ion Chromatograms (EMC/EIC) for a given mass range or a certain m/z value.
    You can also generate UV Traces at a given wavelength from a DAD trace.
    It is very simple to extract UV spectra at selected retention times from a PDA total absorbance chromatogram.

  • In addition to its many tools for structure confirmation by NMR, implemented in the NMR plugin, molecular match is a useful tool for structure confirmation by LC/GC/MS in Mnova MS.
    This functionality is extremely fast and easy to use, making this capability available to all users, even complete novices.
    Import chemical structures and let the software confirm which ones match your experimental data. The match criteria can be customized by selecting the adducts and losses, mass accuracy and score thresholds, etc.

  • The feature allows the user to propose one or multiple molecular formulae and predict their mass peaks with all pre-defined list of adducts or losses.
    Mnova MS predicts a list of molecular ion and isotopic peaks, and automatically matches the predicted peaks with the experimental peaks (if available).
    You can choose which prediction (with desired adduct or loss) to display on the spectrum for comparison.

MSChrom

Videos


Mnova software for MS data processing

MSChrom

FAQs

         Mnova MS supports most of the different MSChrom data formats. You can check it on the MSChrom supported format table here. Please let us know if your MSChrom data format is not in the list.
        You can find the cost of this module in our online store. You can also check out for any combo option if you have or you need Mnova NMR.
         Yes. You can open NMR and MS data in the same document, and cut/paste the MSChrom display to the same page of NMR data if needed. Or you can create a display template to automatically format the reports.
         Yes. Run Molecule Match in Mnova MSChrom to verify the elemental composition automatically, or run Mnova Verify to verify a proposed structure against your MS data (Mnova Verify needs a separate license).
         Yes. Both high resolution and low resolution MS data can be used by Mnova MSChrom. Just make sure you set the proper mass tolerance parameters when you do Molecular Match.
         Yes, you can download a 45-day trial license of any of our products. The Mnova MSChrom module is included within the main Mnova installer. Download Mnova and try it now! Contact us Tel:0532-83818797/18561885100,E-mail:changzhu_ji@tlwb.com.cn

MSChrom

Academic, Government & Industrial

  •      ✯ Teaching MS and Chromatography to chemistry departments
  •      ✯ Research in organic, medicinal and environmental chemistry
  •      ✯ Quality control in chemical and pharmaceutical companies

MSChrom

Contact us

    ✈:No. 377, Nanjing Road, Shibei District, Qingdao, Shandong

    ☏:0532-83818797 / 18561885100

    ✉:changzhu_ ji@tlwb.com.cn

          shuochao_dai@tlwb.com.cn

          support@tlwb.com.cn

 

more

Mnova Combos allow you to enjoy several Mnova plugins at the same time while you get important savings!


Copyright ©2022 . All rights reserved © Qingdao Tenglong Weibo Technology Co.,Ltd. 鲁公网安备 37020302371618 鲁ICP备13025756号-1